P2 專題選修 Specialist Elective · 8 分鐘 / min

水側經濟運轉初步判斷 Water-Side Economizer Feasibility

追蹤室外濕球、冷卻塔與水側換熱的限制。

開啟定量聯算教學 Open the Quantitative Engineering Lab

互動工程卡 Interactive Engineering Card

把物理機制用於場景判斷。 Apply the physical mechanism to a scenario.

室外濕球變低,工程師檢查塔水經熱交換器後是否可供盤管。 Outdoor wet bulb falls, so an engineer checks whether tower water can serve coils through a heat exchanger.

控制或設計判斷以題目工況為限,實案請核對適用要求。 This decision is scoped to the teaching condition. Verify the applicable requirements for real projects.

易錯做法 Common Mistake

只看室外乾球就停用冷水機。 Disable the chiller based solely on outdoor dry bulb.

工程核對 Engineering Check

沿排熱鏈累計各段需要的溫差,並核對可用容量。 Trace the required temperature differences along the heat-rejection path and check available capacity.

延伸至相關知識卡 Continue to Related Cards · 冷卻塔的濕球、溫降與逼近度 Cooling Towers: Wet Bulb, Range and Approach · COP、kW/冷凍噸與部分負荷 COP, kW per Ton and Part Load

冷卻水、換熱器與冷凍水 Condenser Water, Heat Exchanger and Chilled Water

雙迴路水力示意 / Two-loop water circuit 泵 / Pump 冷卻塔 / Cooling tower 泵 / Pump 負載盤管 / Load coil 板式熱交換器 / Plate heat exchanger

冷卻塔逼近溫差 3 K,熱交換器逼近溫差 2 K。例題估算冷卻水供水 6 + 3 = 9 °C,冷凍水可達 9 + 2 = 11 °C,再與 12 °C 目標比。 Assume a 3 K tower approach and 2 K heat exchanger approach. The example estimates 6 + 3 = 9 °C condenser water and 9 + 2 = 11 °C chilled water. Compare that with the 12 °C target.

兩股水隔板換熱。這是溫度條件初判,容量須另核對流量及換熱器資料。 The plate separates the fluids while transferring heat. This is a temperature screen. Verify capacity using flows and exchanger data.

中英術語 Key Terms
水側經濟運轉
water-side economizer
換熱器
heat exchanger
逼近度
approach
負荷端供水
load-side supply water

查術語定義與用法 Look Up Definitions and Usage

學習目標 Learning Objective

說明某些冷濕球工況下,水側經濟運轉如何用換熱器減少機械製冷負荷。

Explain a conditions-based screen for water-side cooling.

核心概念 Key Concepts

適合時,冷卻塔和熱交換器可承擔部分或全部冷量。水路要看兩側是否分離、塔能達到的水溫、換熱器溫差以及末端要求。泵和塔仍會耗電,整體結果須和機械製冷比較。

A tower and exchanger can sometimes carry some or all of the load. Check loop separation, available water temperature, approaches and terminal needs. Pumps and fans still run.

公式與單位 Formulas and Units

  • 做紙上可達性初篩時,用「進風濕球 + 塔逼近度 + 換熱器冷端逼近度」估計負荷側供水溫度,三項以 °C 或 K 溫差一致處理。
  • 總能耗仍按各設備的 kW 和運行時段核對。

Screen load supply with entering wet bulb + tower approach + exchanger cold-end approach. Compare original and alternative energy over the same conditions.

常見錯誤 Common Mistakes

  • 把冷卻塔出水直接當負荷供水。查熱交換器兩側及溫差。
  • 只看氣溫低就認為可供冷。核對濕球、接近溫差、需求與設備限制。

Leaving tower water is not necessarily load supply. Use wet bulb and real operating constraints.

例題 Worked Example

呼出計算器 Open Calculator

濕球 8°C,塔及換熱器各需 3 K 和 2 K 逼近度。供水初估?

  1. 濕球 8°C Wet bulb 8°C
  2. 塔 +3 K、換熱器 +2 K Tower +3 K, exchanger +2 K
  3. 估計供水 13°C Estimated supply 13°C
例題圖解 · 教學工況 Worked Diagram · Teaching Conditions
展開解題步驟 Show Solution

8 + 3 + 2 = 13°C,僅作該負荷下的簡化預估。

完整示範與練習銜接 Worked Method and Practice Bridge

若末端需不高於 12°C,13°C 不能單獨滿足。即使溫度通過,也要按同工況核對水量、換熱量及控制。 If terminal supply must be at or below 12°C, 13°C is too warm. Even if temperature passes, check water flow, exchanger capacity and controls at that duty point.

1 個小練習 Practice Problem

呼出計算器 Open Calculator

虛構條件下濕球 10°C,塔逼近度 3 K,換熱器冷端逼近度 2 K。估算可達供水,對照題給末端要求 14°C,寫下一項需查的工況。

作答後核對答案 Check Answer

10 + 3 + 2 = 15°C,比題給 14°C 高 1 K。可查該水流及冷量下實際塔或換熱器逼近度。

延伸思考與參考 Further Study and References

1 個蘇格拉底式問題 Socratic Question

若室外條件變得更濕而乾球下降,你會先重算哪個量,才能判斷是否仍值得使用水側換熱?

What must be recalculated if dry bulb drops while the air gets wetter?

公開參考連結佔位符 Public Reference Placeholder

〔待導師填入:公開的水側 economizer 及冷卻塔換熱器比較方法〕