P0 核心必學 Core · 7 分鐘 / min

分區、送風與回風路徑 Zoning and Supply/Return Air Paths

從使用時段、負荷與濕度要求劃分區域,再核對送回風路徑。

從一張完整風路圖開始 Start with a Complete Air-Path Diagram

空調箱送風給 A、B 兩區。回風分流回到空調箱或排至室外,B 區另有獨立排風。沿圖中箭頭找出兩條排到室外的支路。 The air handler supplies zones A and B. Return air either recirculates or leaves through relief. Zone B has its own exhaust. Trace both outdoor discharge routes.

    打開 3D + 2D 互動示範 Open the 3D + 2D Demonstration

    互動工程卡 Interactive Engineering Card

    沿系統介面追蹤訊號、空氣或水路。 Trace signals, air or water through system interfaces.

    1. 空調機送出 Supply leaves the AHU
    2. 空氣進入展區 Air enters the gallery
    3. 回風抵達入口 Return reaches its inlet
    A-01 展區由獨立區域送回風,按送風離開設備至回風入口追蹤。 A-01 is separately supplied and returned. Trace air from equipment supply to the return inlet.

    控制或設計判斷以題目工況為限,實案請核對適用要求。 This decision is scoped to the teaching condition. Verify the applicable requirements for real projects.

    易錯做法 Common Mistake

    把送風口旁最近的回風口當作整區已換氣的證據。 Treat the return nearest the diffuser as proof of zone ventilation.

    工程核對 Engineering Check

    沿送風經有人區再到回風。另核對短路與區域遷移。 Follow air through the occupied zone before the return. Check for short-circuiting and transfer between zones.

    延伸至相關知識卡 Continue to Related Cards · CFM 與兩種風量估算 Airflow Estimation in CFM · 風管尺寸、流速與壓降 Duct Sizing, Velocity and Pressure Drop

    中英術語 Key Terms
    分區
    zoning
    送風
    supply air
    回風
    return air
    排風
    exhaust air
    轉移風
    transfer air

    查術語定義與用法 Look Up Definitions and Usage

    學習目標 Learning Objective

    用空間用途、負荷方向和時段說明分區,畫出完整送回風及排風路徑。

    Explain zoning from use, load and schedule. Trace supply, return and exhaust.

    核心概念 Key Concepts

    共用控制區的房間應有可一起回應的需求。若門、氣味或濕度要求不同,分區決策也要考慮空氣如何跨區移動。送風、回風、新風、排風分開標籤,回風口位置與區域內的空氣路徑也會影響均勻度。

    Spaces sharing control should respond similarly. Doors, odors and humidity requirements affect interzone movement. Label supply, return, outdoor and exhaust separately. Return placement and room paths influence uniformity.

    公式與單位 Formulas and Units

    • 同一時段將支路送風以 L/s 加總並對照主管。
    • 房間空氣收支可用同密度近似比較送入及排出,跨區風量要注明方向。

    Sum coincident branch supply in L/s and compare with the main duct. With approximately equal density, account for flows into and out of each room and record transfer direction.

    常見錯誤 Common Mistakes

    • 只按平面格線分區。先比較負荷、占用和濕度。
    • 只畫送風箭頭。補回風、排風、轉移風和門況。

    Do not zone by grid lines alone. Check loads, occupancy and humidity. Include return, exhaust, transfer and door positions.

    例題 Worked Example

    呼出計算器 Open Calculator

    同區兩支送風 95、75 L/s,回風 150 L/s。主管送風和需要說明的餘量?

    1. 送風 95 + 75 L/s Supply 95 + 75 L/s
    2. 回風 150 L/s Return 150 L/s
    3. 剩餘 20 L/s 待查去路 Trace remaining 20 L/s

    對照本卡完整雙區風路 Compare with the Complete Two-Zone Air Path

    例題圖解 · 教學工況 Worked Diagram · Teaching Conditions
    展開解題步驟 Show Solution

    主管送風為 170 L/s,差 20 L/s。畫出轉移風或外洩路徑,並核對是否另有排風。

    完整示範與練習銜接 Worked Method and Practice Bridge

    參照卡上的 AHU 風路圖,在第二區加新風入口、回風分岔、排出風和獨立排風。餘量可經門縫轉移;人數、使用時段、濕度目標及壓力要求會改變分區決策。 Use the AHU diagram to add outdoor intake, return split, relief and dedicated exhaust for a second zone. Transfer may account for the residual. Compare occupancy, schedules, humidity targets and pressure requirements before grouping.

    1 個小練習 Practice Problem

    呼出計算器 Open Calculator

    在兩個虛構房間的空白圖上,標記「常滿觀眾區」和「低濕庫房」,各畫至少一條空氣路徑,列出要分區或合區前需要的資料。

    作答後核對答案 Check Answer

    可畫觀眾區送風到有人區再回風,庫房按自己的溫濕需求畫送回風。分區前查占用時段、濕度目標和門的連通;不能從名稱直接判定分區。

    延伸思考與參考 Further Study and References

    1 個蘇格拉底式問題 Socratic Question

    兩區的人數曲線相近但濕度要求不同時,什麼觀測會讓你放棄共用控制區?

    What observation would justify separate control even when occupancy schedules are similar?

    公開參考連結佔位符 Public Reference Placeholder

    〔待導師填入:公開的 HVAC 分區與送回風平面圖入門〕