P2 專題選修 Specialist Elective · 8 分鐘 / min

廚房熱源、濕氣與工作區舒適 Kitchen Heat, Moisture and Worker Comfort

分開核對罩口捕集、熱負荷、補風溫度與人員位置。

互動工程卡 Interactive Engineering Card

用現有證據選擇下一步查驗。 Use the available evidence to select the next check.

廚房空氣乾球尚可,但近爐操作人員感到很熱。 Air dry bulb seems acceptable, but staff near the range report excessive heat.

控制或設計判斷以題目工況為限,實案請核對適用要求。 This decision is scoped to the teaching condition. Verify the applicable requirements for real projects.

易錯做法 Common Mistake

只靠把送風直接吹向熱羽流改善舒適。 Improve comfort by directing supply air straight at the plume.

工程核對 Engineering Check

乾球只涵蓋一部分熱舒適。核對輻射和氣流,避免破壞罩口捕集。 Dry bulb explains only part of thermal comfort. Check radiation and airflow without disrupting hood capture.

延伸至相關知識卡 Continue to Related Cards · 廚房排煙罩的捕集與圍堵 Kitchen Hood Capture and Containment · 濕度、露點與玻璃冷凝 Humidity, Dew Point and Glass Condensation

中英術語 Key Terms
熱源
heat source
局部風速
local air speed
熱舒適
thermal comfort
直吹
draft

查術語定義與用法 Look Up Definitions and Usage

學習目標 Learning Objective

說明廚房排風合規查驗與人員工作區舒適需要哪些不同資料。

Identify separate evidence for worker comfort and hood performance.

核心概念 Key Concepts

烹調設備可帶來輻射、熱羽流和濕氣。捕集源頭污染和改善人員熱感是兩個查核目標。補風的溫度、方向和速度會影響兩者,直吹操作位置也可能帶來不舒適或干擾罩口。

Cooking produces radiative heat, plumes and moisture. Makeup-air temperature, direction and speed affect capture and comfort. Direct drafts can create discomfort or deflect plumes.

公式與單位 Formulas and Units

  • 空間溫度用 °C,兩測點溫差用 K,相對濕度用 %RH,局部風速用 m/s。
  • 同時記錄烹調活動和測點高度,避免把不同工況混在一起。

Record °C, temperature difference K, %RH and m/s. Match cooking activity and probe height.

常見錯誤 Common Mistakes

  • 只量回風位置。把工作位置、罩口和相鄰區分開量測。
  • 只看冷風能否吹到人。另查側風對羽流與捕集的影響。

Measure at work locations, not just return. Check effect of a cool cross-draft on capture.

例題 Worked Example

呼出計算器 Open Calculator

工作點 28°C,鄰側 26°C,工作點風速 0.8 m/s。要分辨熱和直吹,還要做甚麼?

  1. 操作點 28°C、0.8 m/s Workstation 28°C, 0.8 m/s
  2. 鄰側 26°C Adjacent point 26°C
  3. 罩口與補風口待測 Check hood and makeup inlet
例題圖解 · 教學工況 Worked Diagram · Teaching Conditions
展開解題步驟 Show Solution

記錄同高度的乾球溫度、風向與局部風速,並比較補風開關或其他等效工況;2 K 溫差不能單獨判定成因。

完整示範與練習銜接 Worked Method and Practice Bridge

在操作點同時記乾球與風速,罩口觀察逸散,補風口記出風方向。較熱或風較強都不能單獨證明主因,另查熱源與工況。 Log dry bulb and velocity at the workstation, observe escape at the hood and note the makeup jet direction. Compare heat sources and operating conditions before assigning cause.

1 個小練習 Practice Problem

呼出計算器 Open Calculator

在一張虛構廚房剖面標出操作點、罩口和補風口,為每處設計一個觀測量,說明哪兩項可幫助區分實際熱負荷與直吹。

作答後核對答案 Check Answer

操作點記溫度與風速,罩口觀察熱羽流及可見逸散,補風口記方向和風量。工作點的乾球溫度及局部風速有助分開熱與直吹。

延伸思考與參考 Further Study and References

1 個蘇格拉底式問題 Socratic Question

若增強補風讓工作區更涼,卻在罩邊觀察到羽流逸出,你會如何呈現這項取捨?

How would you explain cooler workers and greater plume escape after a supply change?

公開參考連結佔位符 Public Reference Placeholder

〔待導師填入:公開的商用廚房工作區舒適、補風氣流與污染物控制資料〕