P1 應用延伸 Applied Extension · 8 分鐘 / min

占用變化與需求控制通風 Demand-Controlled Ventilation and Occupancy

用人數與趨勢觀察通風需求,理解 CO₂ 指標的限制。

互動工程卡 Interactive Engineering Card

用現有證據選擇下一步查驗。 Use the available evidence to select the next check.

CO₂ 讀數低,但感測器剛改位置,預期展區即將進人。 CO₂ reads low after a sensor relocation, and visitors will enter shortly.

控制或設計判斷以題目工況為限,實案請核對適用要求。 This decision is scoped to the teaching condition. Verify the applicable requirements for real projects.

易錯做法 Common Mistake

讀值低時將新風停至零。 Stop outdoor airflow whenever the reading is low.

工程核對 Engineering Check

CO₂ 是占用相關訊號;不能單靠該讀數取消其他污染源及最低風量要求。 CO₂ is an occupancy-related signal. It does not override other contaminants or minimum airflow requirements.

延伸至相關知識卡 Continue to Related Cards · 感測器、致動器與點位表 Sensors, Actuators and Point Lists · 室外空氣冷卻與混風判斷 Air-Side Economizer and Mixed Air

中英術語 Key Terms
需求控制通風
demand-controlled ventilation (DCV)
占用
occupancy
二氧化碳
carbon dioxide (CO₂)
室內外濃度差
indoor–outdoor concentration difference

查術語定義與用法 Look Up Definitions and Usage

學習目標 Learning Objective

區分總送風與室外新風,說明占用、CO₂ 及通風核對各需要哪些資料。

Distinguish outdoor airflow from total supply and identify supporting measurements.

核心概念 Key Concepts

人數改變時,按需通風會用占用量或相關訊號調整室外新風,需維持適用的最低通風和約束。人員產生的 CO₂ 在某些條件可輔助判斷,但濃度亦受室外背景、氣流混合和取樣位置影響。其他污染物及濕度仍需另行核對。

Demand control varies outside air using occupancy or related signals within approved limits. Background CO₂, mixing and sensor location affect results. Moisture and other contaminants require separate checks.

公式與單位 Formulas and Units

  • 用百分比表示室外風與總送風的比例,兩股風量需在一致基準下比較。
  • CO₂ 濃度常用 ppm。用室內外差值做趨勢比較,仍需占用與風量證據。

Outdoor-air fraction uses flows on the same basis. Compare indoor minus outdoor CO₂ in ppm with occupant and airflow evidence.

常見錯誤 Common Mistakes

  • 把 CO₂ 當全部空氣品質的代替品。另查氣味、濕度及其他來源。
  • 把總送風下降視為新風等比例下降。對照實際室外風。

CO₂ is not the only air-quality measure. Total supply and outside air can change independently.

例題 Worked Example

呼出計算器 Open Calculator

室內 820 ppm,室外 450 ppm。濃度差多少?

  1. 室內 820 ppm Indoor 820 ppm
  2. 室外 450 ppm Outdoor 450 ppm
  3. 差 +370 ppm Difference +370 ppm
例題圖解 · 教學工況 Worked Diagram · Teaching Conditions
展開解題步驟 Show Solution

820 − 450 = 370 ppm。判讀仍要配合占用和室外送風量等資料。

完整示範與練習銜接 Worked Method and Practice Bridge

若室內相同但室外升到 500 ppm,差只剩 320 ppm。另查人數、時間與新風實測,差值本身不能換成合規結論。 If outdoor rises to 500 ppm with indoor unchanged, the difference becomes 320 ppm. Check occupancy, time and measured outdoor airflow; the difference alone does not establish compliance.

1 個小練習 Practice Problem

呼出計算器 Open Calculator

紙上情境有兩場人數不同的活動。兩段室內 CO₂ 同為 750 ppm,室外分別為 420 和 500 ppm。算差值,列一項必需的占用或風量資料。

作答後核對答案 Check Answer

兩時段分別 330 ppm 及 250 ppm;至少要確認實際人數及活動,或同步的室外風量。相同的室內讀值並不表示條件相同。

延伸思考與參考 Further Study and References

1 個蘇格拉底式問題 Socratic Question

若同一時刻門口和人群中央的 CO₂ 不同,你會怎樣挑選測點,避免草率下結論?

What locations would you sample if the doorway and crowd center disagree?

公開參考連結佔位符 Public Reference Placeholder

〔待導師填入:公開的需求控制通風、CO₂ 與室外風驗證說明〕