P1 應用延伸 Applied Extension · 9 分鐘 / min

混合、置換與特殊送風 Mixing, Displacement and Special Air Distribution

用有人區、浮力與垂直溫差比較混合、置換及大空間氣流。

互動工程卡 Interactive Engineering Card

把物理機制用於場景判斷。 Apply the physical mechanism to a scenario.

某區以低位、低速送入較冷空氣,熱源形成上升羽流。 A zone receives low-velocity cool air from low-level outlets and heat sources create rising plumes.

控制或設計判斷以題目工況為限,實案請核對適用要求。 This decision is scoped to the teaching condition. Verify the applicable requirements for real projects.

易錯做法 Common Mistake

直接假定全室充分混合。 Assume the entire room is fully mixed.

工程核對 Engineering Check

送風高度、溫差與熱羽流方向會改變混合程度及垂直分層。 Supply height, temperature difference and thermal plumes shape mixing and stratification.

延伸至相關知識卡 Continue to Related Cards · 射程、擴散與有人區 Air Throw, Spread and Occupied Zones · 濕度、露點與玻璃冷凝 Humidity, Dew Point and Glass Condensation

中英術語 Key Terms
混合送風
mixing ventilation
置換送風
displacement ventilation
分層
stratification
垂直溫差
vertical temperature difference

查術語定義與用法 Look Up Definitions and Usage

學習目標 Learning Objective

比較混合、低位置換和大空間定向送風,能指出每種型式要量測的風險。

Identify risks and measurement points for different supply patterns.

核心概念 Key Concepts

混合送風常利用射流帶動室內空氣,目標是分布較均勻。置換送風通常用低位較涼的空氣和熱源上升流,會形成垂直分層。大空間可研究定向射流、地板送風或局部送風,需核對幾何、障礙及熱源。

Mixing uses jets and entrainment for uniformity. Low-temperature air supplied at low level can displace air using thermal plumes, creating stratification. Large spaces may use directional jets, floor or local supply.

公式與單位 Formulas and Units

  • 垂直溫差用高處讀值減低處讀值,單位 K,並附兩高度(m)。
  • ADPI 是部分特定混合送風評估的指標,使用前須看量測條件及適用範圍。

Vertical difference = high reading − low reading in K. State heights in m. ADPI only applies under specified mixing and measurement conditions.

常見錯誤 Common Mistakes

  • 把分層等同缺陷。先分辨系統目的和有人區。
  • 用回風溫度當有人區溫度。在不同高度和位置量測。

Stratification is not automatically a failure. Return temperature does not describe every occupied location.

例題 Worked Example

呼出計算器 Open Calculator

近地 22°C,高處 26°C。這兩點的垂直溫差?

  1. 低位測點 22°C Low measurement 22°C
  2. 占用層測點 Occupied-zone measurement
  3. 高位測點 26°C High measurement 26°C
例題圖解 · 教學工況 Worked Diagram · Teaching Conditions
展開解題步驟 Show Solution

26 − 22 = 4 K。還要寫出兩點高度和測量時的送風工況。

完整示範與練習銜接 Worked Method and Practice Bridge

垂直差 4 K。側剖面另畫高位混合送風及低位送風,三點依序核對入風速度、占用區舒適和高處分層,別把兩點當全場。 Vertical difference is 4 K. Sketch high-level mixing and low-level supply separately. Use three points to check inlet velocity, occupied-zone comfort and upper stratification.

1 個小練習 Practice Problem

呼出計算器 Open Calculator

在虛構的高挑觀景廊上畫兩種不同送風路徑,標三個測點,說明每個點要核對氣流、分層或舒適中的哪一項。

作答後核對答案 Check Answer

可畫高處送風混合、低處低速送風後高處回風兩圖。腳踝查風速、坐姿頭高查空氣溫度、上層查分層;在兩圖用同樣位置比較。

延伸思考與參考 Further Study and References

1 個蘇格拉底式問題 Socratic Question

兩種構想都有相同平均室溫,你會如何找出其中一種在腳踝、頭部或觀景點的差異?

How would you distinguish ankle, head and visitor-position conditions at the same average room temperature?

公開參考連結佔位符 Public Reference Placeholder

〔待導師填入:公開的混合、置換、地板送風及大空間空氣分布教學〕